top of page

Hall-IC Contactless Angle Potentiometer

CP-3HABS Series

MIDORI PRECISIONS

CP-3HABS Series

is designed to be ...

  • High ESD rating

  • High resistance to vibration and shock

  • Same mounting flange as QP-3HB series

  • Single/ Dual Output

  • with/ without return spring

Have an evaluation (paid) sample request for this product or any questions about it?        Please contact us.

Product Specifications

CP2HX D_edited.jpg

Electrical Specifications


  • Effective Electrical Travel:  90°

  • Input Voltage: DC5V

  • Absolute Lin:  ±4%FS (FS=90°)

  • Digital Output Resolution:  12bit/Vin

  • Current Consumption:  20mA MAX.


Mechanical Specifications


  • Total Mechanical Travel:  120° Endless

  • Running Torque:  1mN・m MAX.

  • Weight: Approx.30g


Environmental Specifications


  • Category Temp. Range:  -40~+125℃

  • EMS: 100V/m

  • ESD(Case~Each Terminals):±16KV

  • ESD (Each Terminals): ±8KV


APPLICATION EXAMPLES

Bus/ Truck

Engin control.jpg
Transmission control, Clutch stroke sensor, Foot pedal

Forklift

Engin control.jpg
Control lever, Foot pedal

Boat

Engin control.jpg
Remote control lever, Side thruster

DATA SHEET(PDF)/ CAD DATA (DXF)/ CONTACT

CP-3HABS-100-01
CP2HX.jpg

Angle: 90°

Linearity: ±4%FS

Single Output

D-Cut Shaft

CP-3HABS-101-02
CP2HX.jpg

Angle: 90°

Linearity: ±4%FS

Single Output, Return Spring

Double Side Flat Shaft

CP-3HABS-110-01
CP2HX.jpg

Angle: 90°

Linearity: ±4%FS

Single Output

D-Cut Shaft, IP65

CP-3HABS-111-02
CP2HX.jpg

Angle: 90°

Linearity: ±4%FS

Single Output, Return Spring

Double Side Flat Shaft, IP65

CP-3HABS-200-01
CP2HX.jpg

Angle: 90°

Linearity: ±4%FS

Dual Output

D-Cut Shaft

CP-3HABS-201-02
CP2HX.jpg

Angle: 90°

Linearity: ±4%FS

Dual Output, Return Spring

Double Side Flat Shaft

CP-3HABS-210-01
CP2HX.jpg

Angle: 90°

Linearity: ±4%FS

Dual Output

D-Cut Shaft, IP65

CP-3HABS-211-02
CP2HX.jpg

Angle: 90°

Linearity: ±4%FS

Dual Output, Return Spring

Double Side Flat Shaft, IP65

CP2HX.jpg
CP2HX.jpg
CP2HX.jpg
CP2HX.jpg
CP2HX.jpg
CP2HX.jpg
CP2HX.jpg
CP2HX.jpg

HANDLING INSTRUCTION

  • This product can not be used for measurements of the resistance value.

  • This product may be influenced by an external magnetic field.

  • Use this product in an environment protected from ESD.

bottom of page